You can modify the Public and Private time-out value of OWA by Registry Editor.
1. At Exchange Server with Client Access Server role, log in as Domain Administrator.
2. Launch "Registry Editor", navigate to "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlerSet\Services\MSExchange OWA".
3. Right-click "MSExchange OWA", select "New > DWORD (32-bit) Value".
4. Type "PrivateTimeout", press [Enter].
5. Double-click "PrivateTimeout".
6. Select "Decimal", next to "Value data", type a new value.
Remark: A value is in minutes between 1 nd 43,200 for a maximum of 30 days.
7. Click "OK".
8. Right-click "MSExchange OWA", select "New > DWORD (32-bit) Value".
9. Type "PublicTimeout", press [Enter].
10. Double-click "PublicTimeout".
11. Select "Decimal", next to "Value data", type a new value.
12. Click "OK".
Figure 1: The registry value of Public and Private timeout
13. Launch "Exchange Management Shell", enter "Restart-Service MSExchangeFBA".
Remark: You can use the following cmdlets to configure abive settings:
Set-ItemProperty 'HKLM:\SYSTEM\CurrentControlSet\Services\MSExchange OWA' -name PublicTimeout -value <amout of time> -typpe dword
Set-ItemProperty 'HKLM:\SYSTEM\CurrentControlSet\Services\MSExchange OWA' -name PrivateTimeout -value <amout of time> -typpe dword
Reference:
This posting is provided “AS IS” with no warranties, and confers no rights!
No comments:
Post a Comment